CONDICIONES OPTIMAS.·· DE APLICACION DE UN/ NUEVO. INHIBIDOR DE CORROSION ... PARTEI

Authors

  • A. Cepero Centro Nacional de Investigaciones Científicas
  • I. Salgado Centro Nacional de Investigaciones Científicas
  • C. Candedo Centro Nacional de Investigaciones Científicas
  • C. Bauta Centro Nacional de Investigaciones Científicas

Abstract

The characteristics of a new corrosion inhibitor (GIC -1) were evaluated to implement it in the protection
of CT-3 steel in mixtures of hydrochloric acid and ammonium bifluoride at different concentrations and
boiling temperatures. A design of experiments was used to simultaneously evaluate all variations. Equations
were found that allow calculating the corrosion rate, finding good agreement with the results obtained
experimentally.  

Published

1986-05-21

How to Cite

Cepero, A., Salgado, I. ., Candedo , C. ., & Bauta , C. (1986). CONDICIONES OPTIMAS.·· DE APLICACION DE UN/ NUEVO. INHIBIDOR DE CORROSION . PARTEI . NATIONAL CENTER FOR SCIENTIFIC RESEARCH (CENIC) CHEMICAL SCIENCES JOURNAL, 17(1-2), 125-127. Retrieved from https://revista.cnic.cu/index.php/RevQuim/article/view/2466